Applies to: Wisenet WAVE Servers with RAID and running the Megaraid RAID application
Summary:
This article provides the steps to change hard dives that show the Unconfigured Bad drive status to Configured Good in the MegaRAID Storage Manager (MSM) Windows application.
Step By Step Guide:
For MSM Windows Application
To bring the Virtual Drive back online:
- In MSM, click the Logical tab.
- Under Unconfigured Drives, right-click one of the unconfigured drives and select Change to Unconfigured Good.
- Repeat for all of the drives listed as Unconfigured Bad.
The drives will then be listed as (Foreign) Unconfigured Good. - Right-click the Controller ()icon and select Scan Foreign Configuration.
- Select the Import radio button and click OK.
- Click Accept.
- Click Yes.